The channel 1 data streams are available locally as two names pipes,
/tmp/jmb.fifo.1
and /tmp.jmb.fifo.2
. Channel 1 can also be read by a second client using /tmp/jmb.fifo.4
and /tmp/jmb.fifo.5
. If the client for the data streams is on another system, the FIFO outputs can be read by connecting to TCP/IP sockets 1501 and 1502 on the ingest machine. A second client can also read these FIFO outputs by connecting to TCP/IP sockets 1504 and 1505 on the injest machine.
Note, /tmp/jmb.fifo.3 and TCP/IP socket 1503 are reserved for error messages.
If GINI data is ingested, these files are stored on disk in the /data directory.